Specific Search Results Below:
|
| |
|
SRCS |
| |
SRCS, NTURN, CURR, FREQ, PSYM, CSYM
NTURN: Number of turns in the coil winding. Input the total number of windings regardless of the symmetry used in the model.
CURR: Current per turn applied to the coil. Required only for a three-dimensional analysis (the value is calculated for a two-dimensional analysis and is returned as the parameter IWIND).
FREQ: Harmonic frequency of coil current (in Hertz). Required only if terminal voltage (VLTG) is to be calculated. Assumes that eddy currents are neglected.
PSYM: Planar symmetry factor. Used when a symmetric model is used through the cross-section of the coil. The factor is applied to the terminal parameter calculations. For example, if an axisymmetric coil is modeled with symmetry about the X-axis, the symmetry factor would be 2. Defaults to 1.
CSYM: Circumferential symmetry factor. Used only for three-dimensional analysis when a circular-symmetric model is used. For example, if a 90 degree sector is modeled, the symmetry factor (to scale to a full 360 degree model) would be 4. Defaults to 1.
Undocumented at ANSYS 5.7, SRCS is a macro that is still available in the "apdl" subdirectory in ANSYS 11.0. SRCS is limited to linear models. The LMATRIX command, however, is applicable to both linear and nonlinear models, so LMATRIX should be used instead of SRCS.
[permalink]
|
| |
|
Average Rating: 10.0 (4 votes)
|
|
|
| |
|
|