/CONFIG
  /CONFIG,RESUPRES,0
or
RESUPREC=0 in config145.ans

In ANSYS 14.5, stresses, strains, and other element quantities are written in the result file (.rst) as single precision to save space (DOF solution and reaction forces are still written as double-precision). This command, when invoked before solving, will store all results in double-precision.